MERGE_NODE
Part of n8n node configuration official. Install the skill and your agent reads this page when it needs the depth.
Merge node
Merge nodes have two configuration traps. Both fail silently:
- Wrong input count. Merge defaults to 2 inputs. If 3+ sources need to converge, you must explicitly set the input count on the node.
- Off-by-one between
useDataOfInputand.input(n)when porting from existing config.useDataOfInputis 1-indexed (matches UI labels);.input(n)is 0-indexed (matches every other array in code).
Set the input count when you have 3+ sources
The Merge node's numberOfInputs parameter defaults to 2. If you're converging from 3 IF branches, or 4 parallel HTTP calls, or any source-count beyond 2, set it explicitly:
const mergeNode = merge({
config: {
parameters: {
mode: 'append', // or 'combine', etc.
numberOfInputs: 3, // <-- explicit count
},
},
})
Then wire all 3 sources via .input(0), .input(1), .input(2). Verify the parameter name on the user's n8n version via get_node_types for merge — the field name has shifted between versions.
Symptom of forgetting: the workflow validates and runs, but only the first 2 sources' items appear downstream. The third silently drops. Hard to spot in the canvas: the connection line is drawn, the node visually has 3 wires going in, but only 2 inputs exist on the node.
After wiring a Merge with 3+ sources, pull the workflow via get_workflow_details and confirm the parameters.numberOfInputs (or equivalent) matches your wire count.
The translation rule
When porting a workflow or reading useDataOfInput from existing config:
If the source has
useDataOfInput: "N", the wire feeding that slot uses.input(N - 1).
Examples:
| Merge config | Wire to use |
|---|---|
useDataOfInput: "1" |
.input(0) |
useDataOfInput: "2" |
.input(1) |
useDataOfInput: "3" |
.input(2) |
Failure mode
Getting this backward (e.g., .input(2) for useDataOfInput: "2") wires to input index 2 (the third input) instead of index 1 (the second). At runtime:
- The Merge passes through whatever sits at the 1-indexed
useDataOfInputslot, now the wrong source. - Downstream receives data from an unintended upstream branch.
- No error: both inputs are valid, but the contents are just wrong.
Looks identical to a "missing fan-out" because the shape is right but the contents are wrong. Symptoms: downstream conditional logic acts on stale data, and outputs reference real fields with values from a different code path.
Worked example
A Merge with three inputs, configured to pass through Input 2:
Config:
{ "useDataOfInput": "2" }
Correct wiring (using the translation rule, N=2 → .input(1)):
.add(start).to(srcA).to(merge.input(0)) // Input 1: ignored at runtime per useDataOfInput
.add(start).to(srcB).to(merge.input(1)) // Input 2: passed through
.add(start).to(srcC).to(merge.input(2)) // Input 3: ignored
Wrong wiring (matching the numbers):
.add(start).to(srcA).to(merge.input(1)) // ← wrong, srcA on Input 2
.add(start).to(srcB).to(merge.input(2)) // ← wrong, srcB on Input 3
.add(start).to(srcC).to(merge.input(3)) // ← wrong, srcC on (nonexistent) Input 4
At runtime, the wrong wiring passes through srcA's data (because useDataOfInput: "2" selects index 1 = .input(1), now occupied by srcA), not srcB's. The user gets the wrong upstream branch with no clear signal why.
Composite handler shorthand for IF/Switch into Merge
.add(checkType.onTrue(merge.input(0)).onFalse(merge.input(1)))
Pre-2.21.4 this threw MERGE_SINGLE_INPUT: the branch handler hardcoded input index 0 and ignored the .input(n) selector. Since 2.21.4 (n8n#29716) the handler respects the selector and wires the branch to the named input. The universal pattern .add(checkType.output(0).to(merge.input(0))) still works; the shorthand is just shorter for IF/Switch-into-Merge.
Why this exists
The Merge UI predates the SDK. 1-indexed labels match the user's mental model in the editor, and 0-indexed SDK matches every other array in code. Aligning would break one group.
On n8n's roadmap. Until then, use the translation rule.